Tin Whisker Growth Experimental Methods

Experimental Methods

The surface mount device beads under study have two rectangular contacts at opposite sides. With bends of 90 degrees that have an approximate planar surface of 3.048 mm2 each. In order to comply with the standard JESD22-A121, 12 leads on at least 6 components must be examined, with an accumulated lead surface bigger than 75 mm2.

Therefore, 13 SMD beads were used for each one of the three tests (hence, 39 beads of each part type) so that the surface of 13 x 2 contacts x 3.048 = 79 mm2 is above the minimum amount required.

Table 1 : Details on the number of test samples and terminations required for comparison of screening inspection data.

Table 1. Details on the number of test samples and terminations required for comparison of screening inspection data.

Tin Whisker Growth Experimental Methods

Figure 1. A schematic drawing depicting a leadless component and the top and 3 sides of the terminations that should be inspected.

Tin Whisker Growth Experimental Methods

Figure 2. View onto a contact.

The beads were inspected before the tests using a binocular microscope at 72.5x magnification in order to determine if whiskers were present at the beginning of this study.

Tin Whisker Growth Experimental Methods

Detailed inspections were performed on the leads of all the samples from the three lots after each test condition using a scanning electron microscope.

Moreover, and as recommended by the JEDEC standard, a preconditioning heating treatment was applied to all parts prior to start of the test programme.

Tin Whisker Growth Experimental Methods

Figure 3. Temperature profile applied for preconditioning the three lots of 39 SMD beads.

During the screening performed at Alter Technology, each lot of surface mount device beads (39 per part type) was divided in three groups of 13 beads:

The first group of 13 parts was submitted to Temperature Cycling (1000 cycles per run).

The second group of 13 parts was submitted to Ambient Temperature/Humidity Storage (1000 hours per run).

The last group of 13 parts was submitted to High Temperature/Humidity Storage (1000 hours per run).

Each test was repeated four times (or runs) in order to exceed the minimum duration recommended by JEDEC.

Figure 4. Temperature shock test cabinet and humidity chamber.

A summary of the conditions used for testing and a schematic of the test flow are shown in Table 2 and Figure 5 respectively.

Table 2: Tests and conditions applied for accelerating the growth of Stanium whiskers.

Tin Whisker Growth Experimental Methods

Figure 5.Schematic of acceptance test flow carried in Alter Technology on each lot x (x = 1, 2 and 3) of 39 SMD beads. The tests are applicable  for two leaded Class 2 components using Copper (Cu) lead frame with Ni underlay mitigation technology and Stanium (Sn) 100% finish.

Media ATN
Últimas entradas de Media ATN (ver todo)
Tagged as: